Cryo-EM structure of human band 3 dimer from red blood cell
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 4.117 f_angle_d 0.744 f_chiral_restr 0.043 f_plane_restr 0.006 f_bond_d 0.003
Sample Low-salt fraction from human red blood cell membrane
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 530179 Reported Resolution (Å) 4.8 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value 237 Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1800 Maximum Defocus (nm) 3500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 105000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION Topaz IMAGE ACQUISITION SerialEM 3.9 CTF CORRECTION CTFFIND 4.1 INITIAL EULER ASSIGNMENT RELION 3.1 FINAL EULER ASSIGNMENT RELION 3.1 CLASSIFICATION RELION 3.1 RECONSTRUCTION RELION 3.1 MODEL REFINEMENT PHENIX 1.19
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING ONLY 2658315