7TAU

Refined capsid structure of human adenovirus D26 at 3.4 A resolution


ELECTRON MICROSCOPY
Sample
Human adenovirus 26
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentGATAN CRYOPLUNGE 3
Cryogen NameETHANE
Sample Vitrification DetailsBlot for 3 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles30834
Reported Resolution (Å)3.38
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (5TX1)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCorrelation coefficient
Overall B Value150
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)53
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN
Minimum Defocus (nm)800
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification22500
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONLeginon
CTF CORRECTIONCTFFIND4.0
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTcisTEM
CLASSIFICATIONcisTEM
RECONSTRUCTIONcisTEM
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE37026