7T4S

CryoEM structure of the HCMV Pentamer gH/gL/UL128/UL130/UL131A in complex with NRP2 and neutralizing fabs 8I21 and 13H11


ELECTRON MICROSCOPY
Sample
Pentameric complex of HCMV proteins gH, gL, UL128, UL130, UL131A bound to Neuropilin 2 and fabs of human neutralizing antibodies 8I21 and 13H11
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification Detailsblot for 3.5 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles2252924
Reported Resolution (Å)3.1
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsA composite map was generated from the three individual focused 3D maps.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (2QQO, 5VOB)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)52
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONGautomatch0.56
IMAGE ACQUISITIONSerialEM3.7.11
CTF CORRECTIONCTFFIND4.1.13
MODEL FITTINGCoot0.89
INITIAL EULER ASSIGNMENTcisTEM1.02
FINAL EULER ASSIGNMENTcisTEM1.02
CLASSIFICATIONRELION3.1
RECONSTRUCTIONcisTEM1.02
MODEL REFINEMENTPHENIX1.19.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION2532206template-matching particle picking