7ST2

Post translocation, non-rotated 70S ribosome with EF-G dissociated (Structure VII)


ELECTRON MICROSCOPY
Sample
Post translocation, non-rotated 70S ribosome with EF-G dissociated (Structure VII)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles55457
Reported Resolution (Å)2.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id12
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)30.4
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)500
Maximum Defocus (nm)1500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcisTEM
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND
MODEL FITTINGUCSF Chimera
INITIAL EULER ASSIGNMENTFREALIGN
FINAL EULER ASSIGNMENTFREALIGN
CLASSIFICATIONFREALIGN
RECONSTRUCTIONFREALIGN
MODEL REFINEMENTRSRef
MODEL FITTINGUCSF Chimera
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION