7QXS

Cryo-EM structure of human telomerase-DNA-TPP1-POT1 complex (with POT1 side chains)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined36.301
r_long_range_B_other36.301
r_dihedral_angle_2_deg29.665
r_scangle_other25.066
r_mcangle_it23.584
r_mcangle_other23.584
r_scbond_it15.813
r_scbond_other15.813
r_mcbond_it15.124
r_mcbond_other15.121
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined36.301
r_long_range_B_other36.301
r_dihedral_angle_2_deg29.665
r_scangle_other25.066
r_mcangle_it23.584
r_mcangle_other23.584
r_scbond_it15.813
r_scbond_other15.813
r_mcbond_it15.124
r_mcbond_other15.121
r_dihedral_angle_3_deg13.006
r_dihedral_angle_4_deg12.69
r_dihedral_angle_1_deg5.865
r_angle_refined_deg1.358
r_angle_other_deg1.133
r_chiral_restr0.082
r_bond_refined_d0.01
r_gen_planes_refined0.008
r_gen_planes_other0.004
r_bond_other_d0.003
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Complex of telomeric DNA-bound human telomerase with TPP1-POT1
Sample Components
Telomeric DNA
Telomerase reverse transcriptase and telomeric RNA
Histones
TPP1-POT1
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles192871
Reported Resolution (Å)3.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (7BG9, 1XJV, 1XJV)
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)48
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification45871
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION4.0
IMAGE ACQUISITIONEPU2.13.0.3175REL
CTF CORRECTIONCTFFIND4.0
MODEL FITTINGUCSF ChimeraX
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION4.0
FINAL EULER ASSIGNMENTRELION4.0
CLASSIFICATIONRELION4.0
RECONSTRUCTIONRELION4.0
MODEL REFINEMENTREFMAC5.8
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION21589656