7QXA

Cryo-EM map of human telomerase-DNA-TPP1 complex (sharpened)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined47.229
r_long_range_B_other47.229
r_scangle_other32.17
r_mcangle_it31.439
r_mcangle_other31.439
r_dihedral_angle_2_deg28.263
r_scbond_other21.325
r_scbond_it21.324
r_mcbond_it21.319
r_mcbond_other21.292
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined47.229
r_long_range_B_other47.229
r_scangle_other32.17
r_mcangle_it31.439
r_mcangle_other31.439
r_dihedral_angle_2_deg28.263
r_scbond_other21.325
r_scbond_it21.324
r_mcbond_it21.319
r_mcbond_other21.292
r_dihedral_angle_3_deg12.358
r_dihedral_angle_4_deg11.169
r_dihedral_angle_1_deg5.694
r_angle_refined_deg1.067
r_angle_other_deg1.031
r_chiral_restr0.07
r_bond_refined_d0.009
r_gen_planes_refined0.005
r_bond_other_d0.001
r_gen_planes_other0.001
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Complex of telomeric DNA-bound human telomerase with TPP1
Sample Components
Telomeric DNA
Telomerase reverse transcriptase and telomeric RNA
Histones
TPP1
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles144043
Reported Resolution (Å)3.2
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (7BG9)
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)48
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification45872
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU2.13.0.3175REL
CTF CORRECTIONCTFFIND4
MODEL FITTINGUCSF ChimeraX
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot
MODEL REFINEMENTREFMAC5.8
INITIAL EULER ASSIGNMENTRELION4
FINAL EULER ASSIGNMENTRELION4
CLASSIFICATIONRELION4
RECONSTRUCTIONRELION4.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION18744992