7QW9

Cryo-EM structure of coxsackievirus A6 mature virion


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg33.01
r_long_range_B_refined20.96
r_long_range_B_other20.96
r_dihedral_angle_4_deg15.267
r_mcangle_it14.59
r_mcangle_other14.59
r_dihedral_angle_3_deg13.134
r_scangle_other12.954
r_mcbond_it10.258
r_mcbond_other10.257
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg33.01
r_long_range_B_refined20.96
r_long_range_B_other20.96
r_dihedral_angle_4_deg15.267
r_mcangle_it14.59
r_mcangle_other14.59
r_dihedral_angle_3_deg13.134
r_scangle_other12.954
r_mcbond_it10.258
r_mcbond_other10.257
r_scbond_other9.006
r_scbond_it9.005
r_dihedral_angle_1_deg6.58
r_angle_refined_deg1.572
r_angle_other_deg1.284
r_chiral_restr0.063
r_bond_refined_d0.012
r_gen_planes_refined0.007
r_bond_other_d0.002
r_gen_planes_other0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Coxsackievirus A6
Sample Components
Capsid
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles1769
Reported Resolution (Å)2.68
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (5XS4)
Refinement SpaceRECIPROCAL
Refinement ProtocolRIGID BODY FIT
Refinement Targetcorrelation coefficient
Overall B Value66
Fitting Procedure
Detailsiterative cycles of building - real space refinement - reciprocal space refinement
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)45
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcrYOLO
IMAGE ACQUISITIONEPU1.12
CTF CORRECTIONGctf1.06
MODEL FITTINGUCSF Chimera
MODEL REFINEMENTCoot0.9.5
MODEL REFINEMENTPHENIX1.19.2
MODEL REFINEMENTREFMAC5
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION211991