7QEO

human Connexin 26 at 55mm Hg PCO2, pH7.4: two masked subunits, class C


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d7.2082
f_angle_d0.6078
f_chiral_restr0.0418
f_bond_d0.0061
f_plane_restr0.0032
Sample
two subunits masked from dodecameric assembly of human connexin 26: class C
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE-PROPANE
Sample Vitrification Details3 microlitres protein applied to grid, blot time 6 seconds, in 10% CO2/90%N2 atmosphere
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles18750
Reported Resolution (Å)2.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (2ZW3)
Refinement SpaceREAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)45
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
IMAGE ACQUISITIONEPU2.X
CTF CORRECTIONGctf
MODEL FITTINGCoot0.8.9.2 EL
MODEL REFINEMENTPHENIX1.18.2-3874
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1679668LoG picker implemented in Relion3.1-beta