7AU2

Cryo-EM structure of human exostosin-like 3 (EXTL3)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d21.788
f_angle_d0.655
f_chiral_restr0.047
f_bond_d0.005
f_plane_restr0.005
Sample
Homodimer of EXTL3 globular domain
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles171285
Reported Resolution (Å)2.43
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)71.4
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONGctf1.06
MODEL FITTINGBuccaneer
MODEL FITTINGCoot
MODEL FITTINGISOLDE
MODEL REFINEMENTPHENIX1.18.2
INITIAL EULER ASSIGNMENTRELION2.1
FINAL EULER ASSIGNMENTRELION2.1
CLASSIFICATIONRELION2.1
RECONSTRUCTIONRELION2.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION656292