6I3M

eIF2B:eIF2 complex, phosphorylated on eIF2 alpha serine 52.


ELECTRON MICROSCOPY
Sample
Complex of translation initiation factors eIF2 and eIF2B
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification DetailsBlot for 2 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles64541
Reported Resolution (Å)3.93
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (5B04, 3JAP)2 (3JAP, 3JAP, 3JAP)
Refinement SpaceREALREAL
Refinement ProtocolFLEXIBLE FITRIGID BODY FIT
Refinement Targetcorrelation coeficientCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsModeller was used to build homology model of S. cerevisiae eIF2B structure based on S. pombe crystal structure. Subunits of the homology model, along ...Modeller was used to build homology model of S. cerevisiae eIF2B structure based on S. pombe crystal structure. Subunits of the homology model, along with eIF2 alpha domains 1 and 2, were then rigid body fitted into our map using UCSF Chimera. The model then was refined using phenix and manually adjusted in Coot.
eIF2 alpha domain 3, eIF2 gamma, and eIF2 beta (3JAP) were rigid body fitted into our map using Chimera.
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification37313
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsTilt at zero and 35 degrees.
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION2.01
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf
MODEL FITTINGMODELLER
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION2.1
FINAL EULER ASSIGNMENTRELION2.1
CLASSIFICATIONRELION2.1
RECONSTRUCTIONRELION2.1
MODEL REFINEMENTPHENIX
MODEL FITTINGUCSF Chimera
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONCTF determination was performed per micrograph initially. After particle picking and initial reconstruction, per particle CTF determination was performed.655000Initially, approximately 3000 particles were picked manually and used for 2D classification. Then 4 best looking 2D class average images were used as references for automated particle picking in RELION. For the zero tilt data collection, 406000 particles were picked. For the 35 degree tilt data collection, 249000 particles were picked