6X5Z

Bovine Cardiac Myosin in Complex with Chicken Skeletal Actin and Human Cardiac Tropomyosin in the Rigor State


ELECTRON MICROSCOPY
Sample
Helical complex of bovine S1 cardiac myosin and human cardiac tropomyosin-decorated chicken skeletal actin filaments
Sample Components
skeletal actin filaments
S1 cardiac myosin
cardiac tropomyosin
Specimen Preparation
Sample Aggregation StateHELICAL ARRAY
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification DetailsThin filaments were reconstituted by first mixing F-actin and tropomyosin to final concentrations of 10 uM actin and 7 uM tropomyosin. Just before app ...Thin filaments were reconstituted by first mixing F-actin and tropomyosin to final concentrations of 10 uM actin and 7 uM tropomyosin. Just before applying 1.5 uL actin-tropomyosin to a freshly glow discharged holey-carbon grid, the surfactant octyl B-D-glucopyranoside was added to the protein solution to a concentration of 12 nM. The grid sample was manually blotted for 1 second and a 1.5 uL drop of 7.5 uM myosin-S1 sub-fragment was then applied to the blotted grid sample. The sample was immediately blotted for 4 seconds and plunge-frozen in liquid ethane.
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles32158
Reported Resolution (Å)4.24
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsPerformed in the Relion post-processing step
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise27.5
Angular Rotation-166.4
Map-Model Fitting and Refinement
Id1 (6KN8, 3I5G)23
Refinement SpaceREALREALREAL
Refinement ProtocolFLEXIBLE FITOTHEROTHER
Refinement Target
Overall B Value70.88
Fitting Procedureflexible fittingreal space refinementmanual refinement
Detailsversion 1.9.3; initial flexible fitting to align secondary structure using MDFFversion 1.18-3861manual refinement of residues to match backbone and sidechain density and to limit clashes, sidechain outliers, and Ramachandran outliers
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)53
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification130000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0.7
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1
INITIAL EULER ASSIGNMENTRELION3.0.7
FINAL EULER ASSIGNMENTRELION3.0.7
RECONSTRUCTIONRELION
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION45040