6WCJ

Asymmetric vertex of the clathrin minicoat cage


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d6.8189
f_angle_d0.3393
f_chiral_restr0.0328
f_plane_restr0.0028
f_bond_d0.0012
Sample
Natively assembled clathrin coated vesicles
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles305413
Reported Resolution (Å)6.3
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsAfter the final refinement in cisTEM, half-maps were generated in cisTEM and the FSC was calculated with EMAN FSC tools.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (6SCT, 6SCT, 6SCT)2 (6SCT, 6SCT, 6SCT)3 (6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT, 6SCT)
Refinement Space
Refinement ProtocolAB INITIO MODELAB INITIO MODELFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)3000
Maximum Defocus (nm)5000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification35000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3
IMAGE ACQUISITIONLeginon
CTF CORRECTIONcisTEM1
CTF CORRECTIONCTFFIND4
CTF CORRECTIONRELION3
MODEL FITTINGRosetta
INITIAL EULER ASSIGNMENTcryoSPARC2
FINAL EULER ASSIGNMENTcisTEM1
FINAL EULER ASSIGNMENTRELION3
RECONSTRUCTIONcisTEM1
MODEL REFINEMENTPHENIX
MODEL FITTINGRosetta
MODEL REFINEMENTPHENIX
MODEL FITTINGRosetta
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION360000These are subparticle images that were extracted from particle images. Each minicoat particle has 24 asymmetric vertices. From a total of 15000 minicoat particles, 360000 vertex subparticles were extracted. The position of subparticles was calculated by the localized reconstruction script in scipion, and the subparticle images were extracted with RELION extraction tools.