6U3G

Best fitting antiparallel model for Volume 2 of truncated dimeric Cytohesin-3 (Grp1; amino acids 14-399)


ELECTRON MICROSCOPY
Sample
Truncated homodimer of Cytohesin-3 (Grp1, amino acids 14-399) with Inositol 1,3,4,5-tetrakis phosphate (IP4)
Specimen Preparation
Sample Aggregation StatePARTICLE
Staining TypeNEGATIVE
Staining MaterialUranyl Formate
Staining DetailsStained with 0.75% (w/v) uranyl formate
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles1863
Reported Resolution (Å)53
Resolution MethodFSC 0.5 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (2R09)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetCorrelation coefficient
Overall B Value
Fitting Procedure
DetailsThe model with the best correlation coefficient was selected by ADP_EM from a pool of 10000 models generated by RRT_SAMPLE using rigid bodies derived ...The model with the best correlation coefficient was selected by ADP_EM from a pool of 10000 models generated by RRT_SAMPLE using rigid bodies derived from 2R09 (autoinhibited core, amino acids 63-399) and a canonical antiparallel coiled coil (amino acids 18-53) built with CCBuilder. Flexible regions with reasonable geometry were modeled with MODELLER.
Data Acquisition
Detector TypeTVIPS TEMCAM-F224 (2k x 2k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI/PHILIPS CM120T
Minimum Defocus (nm)-1200
Maximum Defocus (nm)-3200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification28000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)120
Imaging Detailsspecimen holder: FISCHIONE INSTRUMENTS DUAL AXIS TOMOGRAPHY HOLDER
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONEMAN22.12
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONEMAN22.12
MODEL FITTINGADP_EM0.99
CLASSIFICATIONEMAN22.12
RECONSTRUCTIONEMAN22.12
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION6504Particles were manually picked.