6QJH

Cryo-EM structure of heparin-induced 2N4R tau snake filaments


ELECTRON MICROSCOPY
Sample
heparin-induced 2N4R tau snake filaments
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsBlot force: -12 ; Blot time: 4s
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles52441
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.7
Angular Rotation-1.26
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement TargetFourier shell correlation
Overall B Value41.26
Fitting Procedure
DetailsA stack of three consecutive monomers was refined to preserve nearest-neighbour interactions for the middle chain. Side-chain clashes were detected us ...A stack of three consecutive monomers was refined to preserve nearest-neighbour interactions for the middle chain. Side-chain clashes were detected using MOLPROBITY, and corrected by iterative cycles of real-space refinement in COOT and Fourier-space refinement in REFMAC and PHENIX. For each refined structure, separate model refinements were performed against a single half-map, and the resulting model was compared to the other half-map to confirm the absence of overfitting.
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)48
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI POLARA 300
Minimum Defocus (nm)1700
Maximum Defocus (nm)2800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder ModelGATAN LIQUID NITROGEN
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONEPU1.5.0.1243REL
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot0.8.9.1
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
CLASSIFICATIONRELION3.0
RECONSTRUCTIONRELION3.0
MODEL REFINEMENTREFMAC5.8.0236
MODEL REFINEMENTPHENIXdev-2919-000
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONAligned, non-dose-weighted micrographs were used to estimate the contrast transfer function (CTF) using CTFFIND4.1303754Manually picked