6LQT

Cryo-EM structure of 90S small subunit preribosomes in transition states (State E)


ELECTRON MICROSCOPY
Sample
90S pre-ribosome (Dhr1-depleted, state E)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles14475
Reported Resolution (Å)4.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (6LQS)
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND4.1.8
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTRELION
CLASSIFICATIONRELION
RECONSTRUCTIONRELION
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION382298