☰ Navigation Tabs
The partially disordered conformation of ubiquitin (Q41N variant)
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 HSQC-NOESY 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE III 800 2 2D 1H-15N HSQC 0.3 mM [U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 3 3D CBCA(CO)NH 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 4 3D HNCACB 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 5 3D HNCA 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 6 3D HN(CO)CA 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 7 3D HNCO 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 8 3D HN(CA)CO 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 9 3D HBHA(CO)NH 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 10 3D HCC(CO)NH 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 11 3D CC(CO)NH 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 12 3D HCCH-TOCSY 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 13 3D CCH-TOCSY 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600 14 3D TOCSY-HSQC 1.0 mM [U-99% 13C; U-99% 15N] ubiquitin, 30 mM D D-acetate 90% H2O/10% D2O 30 mM 4.0 2500 bar 278 Bruker AVANCE 600
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE 600 2 Bruker AVANCE III 800
NMR Refinement Method Details Software torsion angle dynamics CYANA
NMR Ensemble Information Conformer Selection Criteria structures with the least restraint violations Conformers Calculated Total Number 1900 Conformers Submitted Total Number 20 Representative Model 1 (lowest energy)
Computation: NMR Software # Classification Version Software Name Author 1 structure calculation CYANA 3.98.omp Guntert, Mumenthaler and Wuthrich 2 chemical shift assignment KUJIRA Naohiro Kobayashi 3 refinement CYANA Guntert, Mumenthaler and Wuthrich