Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
3 ul of sample were applied on the resulting glow-discharged grids and excess solution was blotted during 2.5 sec force 7
3D Reconstruction
Reconstruction Method
HELICAL
Number of Particles
105665
Reported Resolution (Å)
3.3
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
HELICAL
Axial Symmetry
C1
Axial Rise
18.87
Angular Rotation
-99.95
Map-Model Fitting and Refinement
Id
1 (5FSG)
Refinement Space
REAL
Refinement Protocol
AB INITIO MODEL
Refinement Target
Overall B Value
103
Fitting Procedure
Details
Fiber model was iteratively rebuilt and all-atom refined using stereochemical and NCS restraints
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)
40
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
46860
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
RELION
2.1
IMAGE ACQUISITION
EPU
CTF CORRECTION
Gctf
CTF CORRECTION
Gctf
CTF CORRECTION
RELION
3.0
MODEL FITTING
UCSF Chimera
INITIAL EULER ASSIGNMENT
RELION
2.1
FINAL EULER ASSIGNMENT
RELION
2.1
RECONSTRUCTION
RELION
3.0
MODEL REFINEMENT
PHENIX
1.13
MODEL REFINEMENT
Coot
0.8.9
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
168709
Straight HTNV-NC were manually picked and computationally cut with an inter-box distance of 38 A along the helical axis into overlapping boxes of 400*400 pixels, resulting in 168,709 extracted segments. 2D classification was used to eliminate bad quality filaments.