6E8G

CryoEM reconstruction of IST1-CHMP1B copolymer filament bound to ssDNA at 2.9 Angstrom resolution


ELECTRON MICROSCOPY
Sample
Helical assembly of IST1 and CHMP1B protein bound to ssDNA
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details0 mm offset with 10 sec wait time and 2-4 sec blot
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles101990
Reported Resolution (Å)2.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise3.17
Angular Rotation21.16
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value52.5
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)62
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.6
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification29000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION2.1
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONGctf1.06
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION2.1
FINAL EULER ASSIGNMENTRELION2.1
CLASSIFICATIONRELION2.1
RECONSTRUCTIONRELION2.1
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION224252Helical particle segments were selected using RELION manualpick and extracted using overlapping segments with an asymmetric unit of 17 subunits with a 3.0 Angstrom rise (51 Angstrom total).