6BVU
SFTI-HFRW-1
SOLUTION NMR
NMR Experiment | ||||||||
---|---|---|---|---|---|---|---|---|
Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
1 | 2D 1H-1H NOESY | 1 mM AZ2 | 90% H2O/10% D2O | 3.5 | 1 Pa | 298 | Bruker AVANCE III 600 | |
2 | 2D 1H-1H TOCSY | 1 mM AZ2 | 90% H2O/10% D2O | 3.5 | 1 Pa | 298 | Bruker AVANCE III 600 | |
3 | 2D 1H-13C HSQC | 1 mM AZ2 | 90% H2O/10% D2O | 3.5 | 1 Pa | 298 | Bruker AVANCE III 600 | |
4 | 2D 1H-15N HSQC | 1 mM AZ2 | 90% H2O/10% D2O | 3.5 | 1 Pa | 298 | Bruker AVANCE III 600 | |
5 | 2D 1H-1H COSY | 1 mM AZ2 | 90% H2O/10% D2O | 3.5 | 1 Pa | 298 | Bruker AVANCE III 600 |
NMR Spectrometer Information | |||
---|---|---|---|
Spectrometer | Manufacturer | Model | Field Strength |
1 | Bruker | AVANCE III | 600 |
NMR Refinement | ||
---|---|---|
Method | Details | Software |
torsion angle dynamics | CYANA |
NMR Ensemble Information | |
---|---|
Conformer Selection Criteria | structures with the least restraint violations |
Conformers Calculated Total Number | 50 |
Conformers Submitted Total Number | 20 |
Representative Model | 1 (fewest violations) |
Computation: NMR Software | ||||
---|---|---|---|---|
# | Classification | Version | Software Name | Author |
1 | peak picking | CcpNMR | CCPN | |
2 | refinement | CYANA | 3.97 | Guntert, Mumenthaler and Wuthrich |
3 | chemical shift assignment | CcpNMR | CCPN | |
4 | collection | TopSpin | Bruker Biospin | |
5 | structure calculation | CYANA | Guntert, Mumenthaler and Wuthrich |