SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
12D 1H-1H TOCSY0.1 mg/mL CcoTx-II90% H2O/10% D2O6ambient Pa298Bruker AVANCE 600
22D 1H-1H NOESY0.1 mg/mL CcoTx-II90% H2O/10% D2O6ambient Pa298Bruker AVANCE 600
32D 1H-15N HSQC0.1 mg/mL CcoTx-II90% H2O/10% D2O6ambient Pa298Bruker AVANCE 600
42D 1H-13C HSQC0.1 mg/mL CcoTx-II100% D2O6ambient Pa298Bruker AVANCE 600
52D 1H-1H TOCSY0.1 mg/mL CcoTx-II100% D2O6ambient Pa298Bruker AVANCE 600
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE600
NMR Refinement
MethodDetailsSoftware
simulated annealingCNS
NMR Ensemble Information
Conformer Selection Criteriastructures with the least restraint violations
Conformers Calculated Total Number50
Conformers Submitted Total Number20
Representative Model1 (fewest violations)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1processingTopSpinBruker Biospin
2chemical shift assignmentCcpNMRCCPN
3structure calculationCYANAGuntert, Mumenthaler and Wuthrich
4refinementCNSBrunger, Adams, Clore, Gros, Nilges and Read