6BNP

CryoEM structure of MyosinVI-actin complex in the rigor (nucleotide-free) state


ELECTRON MICROSCOPY
Sample
myosin VI-actin in the rigor (nucleotide-free) state
Sample Components
myosin VI
actin
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification DetailsSample was applied to a glow-discharged holey carbon grid. 3 uL actin was incubated for 60 seconds. 3 uL of myosin VI was added and incubated for 60 ...Sample was applied to a glow-discharged holey carbon grid. 3 uL actin was incubated for 60 seconds. 3 uL of myosin VI was added and incubated for 60 seconds. 3 uL solution was removed. An additional 3 uL of myosin VI was applied. After 60 seconds, 3 uL solution was removed, and the grid was blotted for 3 seconds from the backside with filter paper.
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles56116
Reported Resolution (Å)4.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise28.06
Angular Rotation-166.73
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value150
Fitting Procedure
DetailsInitial models were assembled from 8 actins (3J8A) and 6 myosins (2BKI) through rigid body docking in Chimera, followed by flexible fitting with DireX ...Initial models were assembled from 8 actins (3J8A) and 6 myosins (2BKI) through rigid body docking in Chimera, followed by flexible fitting with DireX. Resulting models were subjected to MDFF.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)1.5
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TECNAI 20
Minimum Defocus (nm)1500
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder ModelGATAN 626 SINGLE TILT LIQUID NITROGEN CRYO TRANSFER HOLDER
Nominal Magnification29000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONAppion
IMAGE ACQUISITIONLeginon
CTF CORRECTIONCTFFIND
CTF CORRECTIONFREALIGN9.11
MODEL FITTINGDireX
MODEL FITTINGMDFF
MODEL FITTINGNAMD
MODEL REFINEMENTMDFF
INITIAL EULER ASSIGNMENTEMAN2
INITIAL EULER ASSIGNMENTSPARX
FINAL EULER ASSIGNMENTFREALIGN9.11
RECONSTRUCTIONFREALIGN9.11
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION