5VN8

Cryo-EM model of B41 SOSIP.664 in complex with fragment antigen binding variable domain of b12


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.194
f_angle_d1.133
f_chiral_restr0.065
f_plane_restr0.007
f_bond_d0.006
Sample
HIV-1 Env B41 SOSIP.664 in complex with b12 fragment antigen binding
Sample Components
HIV-1 Env B41 SOSIP.664
b12 fragment
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification Details3 uL of sample applied to a holey carbon grid on glow discharged face and blotted manually on sample side until filter paper detached from grid, follo ...3 uL of sample applied to a holey carbon grid on glow discharged face and blotted manually on sample side until filter paper detached from grid, followed by immediate plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles88071
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC3
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetEMRinger
Overall B Value
Fitting Procedure
DetailsHomology model of B41 SOSIP.664 created using PDB 5CEZ as initial model. b12 coordinates taken from PDB 2NY7. Performed fragment based refinement usin ...Homology model of B41 SOSIP.664 created using PDB 5CEZ as initial model. b12 coordinates taken from PDB 2NY7. Performed fragment based refinement using Rosetta, followed by relaxed refinement in Rosetta. Modeled glycans using Chimera and performed final refinements using Phenix.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)58
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification22500
Calibrated Magnification38168
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONLeginon
CTF CORRECTIONGctf1.06
MODEL FITTINGUCSF Chimera1.10.1
MODEL REFINEMENTRosetta2016.02.58402
MODEL REFINEMENTPHENIX1.11.1-2575
INITIAL EULER ASSIGNMENTRELION2.0
FINAL EULER ASSIGNMENTRELION2.0
CLASSIFICATIONRELION2.0
RECONSTRUCTIONRELION2.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION