Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Structure of calcium-free mTMEM16A chloride channel at 4.06 A resolution
ELECTRON MICROSCOPY
Refinement
RMS Deviations
Key
Refinement Restraint Deviation
r_dihedral_angle_2_deg
30.514
r_long_range_B_refined
16.866
r_long_range_B_other
16.865
r_dihedral_angle_3_deg
14.099
r_dihedral_angle_4_deg
13.844
r_scangle_other
10.241
r_mcangle_it
9.597
r_mcangle_other
9.597
r_dihedral_angle_1_deg
6.217
r_scbond_it
5.664
RMS Deviations
Key
Refinement Restraint Deviation
r_dihedral_angle_2_deg
30.514
r_long_range_B_refined
16.866
r_long_range_B_other
16.865
r_dihedral_angle_3_deg
14.099
r_dihedral_angle_4_deg
13.844
r_scangle_other
10.241
r_mcangle_it
9.597
r_mcangle_other
9.597
r_dihedral_angle_1_deg
6.217
r_scbond_it
5.664
r_scbond_other
5.664
r_mcbond_it
5.315
r_mcbond_other
5.314
r_angle_other_deg
3.701
r_angle_refined_deg
1.295
r_chiral_restr
0.105
r_bond_refined_d
0.007
r_gen_planes_refined
0.005
r_gen_planes_other
0.004
r_bond_other_d
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
mTMEM16A in absence of calcium ions
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
2 ul sample volume
2-4 sec blotting time
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
195465
Reported Resolution (Å)
4.06
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
Id
1
Refinement Space
Refinement Protocol
RIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)
80
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
500
Maximum Defocus (nm)
3800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
36630
Calibrated Magnification
36630
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
RELION
2.1b1
IMAGE ACQUISITION
SerialEM
CTF CORRECTION
CTFFIND
4.1.8
MODEL FITTING
Coot
MODEL REFINEMENT
PHENIX
MODEL REFINEMENT
REFMAC
5
INITIAL EULER ASSIGNMENT
RELION
21b1
FINAL EULER ASSIGNMENT
RELION
2.1b1
CLASSIFICATION
RELION
2.1b1
RECONSTRUCTION
RELION
2.1b1
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
The contrast transfer function (CTF) parameters were estimated on the movie frames by ctffind4.1
1349821
For the dataset collected in absence of calcium ions a total of 5063 dose-fractionated super-resolution images were recorded, 2 x 2 down-sampled by Fourier cropping (final pixel size 1.365A) and subjected to motion correction and dose-weighting of frames by MotionCor2. The contrast transfer function (CTF) parameters were estimated on the movie frames by ctffind4.1. Images showing a strong drift, higher defocus than -3.8 um or a bad CTF estimation were discarded, From a total of 4,738 images (final pixel size 1.365 A) 1,349,821 particles were extracted with a box size of 256 pixels after auto-picking and initial round of 2D classification. Initial rounds of 2D and 3D classification, resulted in a set of 467,286 particles which where subjected to particle polishing, as described above, as well as final rounds of 3D classification. The final polished and auto-refined map was calculated from 195,465 particles derived from 4726 images with a resolution of 4.86 A before masking and 4.06 A after masking and was sharpened using an isotropic b-factor of -116 A2