ELECTRON MICROSCOPY
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| r_long_range_B_refined | 89.082 |
| r_long_range_B_other | 89.082 |
| r_scangle_other | 64.304 |
| r_mcangle_it | 58.665 |
| r_mcangle_other | 58.663 |
| r_scbond_it | 39.267 |
| r_scbond_other | 39.265 |
| r_mcbond_it | 36.53 |
| r_mcbond_other | 36.529 |
| r_dihedral_angle_2_deg | 26.452 |
| Sample |
|---|
| TFIIH |
| Sample Components |
| TFIIH core complex |
| TFIIH CDK-activating kinase (CAK) subcomplex |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | 3-4 minute incubation, 2 second blot |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 122900 |
| Reported Resolution (Å) | 4.4 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | RELION 3D auto-refinement (gold standard). |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | Initial model assembled from high-resolution structures and homology models. Subsequently rebuilt in O and COOT, refined into the cryo-EM map using PH ... | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 40 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN |
| Minimum Defocus (nm) | 2000 |
| Maximum Defocus (nm) | 4500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | GATAN 626 SINGLE TILT LIQUID NITROGEN CRYO TRANSFER HOLDER |
| Nominal Magnification | |
| Calibrated Magnification | 37879 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| IMAGE ACQUISITION | Leginon | |
| CTF CORRECTION | CTFFIND | 4 |
| MODEL FITTING | UCSF Chimera | |
| MODEL FITTING | O | |
| MODEL FITTING | Coot | |
| INITIAL EULER ASSIGNMENT | RELION | 1.4 |
| FINAL EULER ASSIGNMENT | RELION | 1.4 |
| CLASSIFICATION | RELION | 1.4 |
| RECONSTRUCTION | RELION | 1.4 |
| MODEL REFINEMENT | PHENIX | development versions |
| MODEL REFINEMENT | REFMAC | 5.9 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | Correction in RELION based on values determined in CTFFIND4. | 1500000 | Initial rounds of particle selection using DogPicker within APPION to generate templates for subsequent RELION autopicking. | |