SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
13D 1H-15N NOESY10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX800 800
23D 1H-13C NOESY10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX800 800
33D HNCA10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX500 500
43D HNCACB10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX500 500
53D CBCA(CO)NH10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX500 500
83D HNCO10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX500 500
73D HBHA(CO)NH10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX500 500
63D 1H-15N TOCSY10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX500 500
92D 1H-15N HSQC10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX800 800
102D 1H-13C HSQC10 mg/L [U-99% 13C; U-99% 15N] GATA2 Zinc Finger 290% H2O/10% D2O150 mM71 Pa273Bruker DRX800 800
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerDRX500500
2BrukerDRX800800
NMR Refinement
MethodDetailsSoftware
simulated annealingARIA
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number100
Conformers Submitted Total Number20
Representative Model1 (lowest energy)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1refinementARIA2.3Linge, O'Donoghue and Nilges
2structure calculationARIA2.3Linge, O'Donoghue and Nilges
3chemical shift assignmentCcpNmr Analysis2.4.1CCPN
4peak pickingCcpNmr Analysis2.4.1CCPN