5NUG

Motor domains from human cytoplasmic dynein-1 in the phi-particle conformation


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg32.415
r_long_range_B_refined23.437
r_long_range_B_other23.437
r_dihedral_angle_3_deg14.806
r_scangle_other14.522
r_mcangle_it13.025
r_mcangle_other13.025
r_dihedral_angle_4_deg11.811
r_scbond_it7.906
r_scbond_other7.906
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg32.415
r_long_range_B_refined23.437
r_long_range_B_other23.437
r_dihedral_angle_3_deg14.806
r_scangle_other14.522
r_mcangle_it13.025
r_mcangle_other13.025
r_dihedral_angle_4_deg11.811
r_scbond_it7.906
r_scbond_other7.906
r_mcbond_it7.438
r_mcbond_other7.438
r_dihedral_angle_1_deg5.677
r_angle_refined_deg1.301
r_angle_other_deg0.915
r_chiral_restr0.083
r_bond_refined_d0.008
r_gen_planes_refined0.005
r_bond_other_d0.002
r_gen_planes_other0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Motor domains from human cytoplasmic dynein-1 in the phi-particle conformation
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles233227
Reported Resolution (Å)3.8
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value145
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)1.6
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)5000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification59000
Calibrated Magnification106061
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONGautomatch0.53
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf1.06
MODEL FITTINGCoot0.83
INITIAL EULER ASSIGNMENTRELION1.4
FINAL EULER ASSIGNMENTRELION1.4
CLASSIFICATIONRELION1.4
RECONSTRUCTIONRELION1.4
MODEL REFINEMENTREFMAC5.8.0166
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1Negative stain dataset was processed to generate templates.