Atomic structure of P4 packaging enzyme fitted into a localized reconstruction of bacteriophage phi6 vertex
ELECTRON MICROSCOPY
Crystallization
| Crystalization Experiments | ||||
|---|---|---|---|---|
| ID | Method | pH | Temperature | Details |
| 1 | 8 | 6% PEG 4000 AND 90 MM SODIUM ACETATE PH 4.5 | ||
| Crystal Properties | |
|---|---|
| Matthews coefficient | Solvent content |
| 2.3 | 46 |
Diffraction
| Radiation Source | |||||
|---|---|---|---|---|---|
| ID # | Source | Type | Wavelength List | Synchrotron Site | Beamline |
| 1 | SYNCHROTRON | SRS BEAMLINE PX14.2 | SRS | PX14.2 | |
Data Collection
| Overall | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID # | Resolution (High) | Resolution (Low) | Percent Possible (Observed) | R Merge I (Observed) | Net I Over Average Sigma (I) | Redundancy | Number Reflections (All) | Number Reflections (Observed) | Observed Criterion Sigma (F) | Observed Criterion Sigma (I) | B (Isotropic) From Wilson Plot | ||||||||
| 1 | 2.8 | 20 | 97 | 0.19 | 8.3 | 3 | 72831 | 1.5 | 51.06 | ||||||||||
| Highest Resolution Shell | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ID # | Resolution (High) | Resolution (Low) | Percent Possible (All) | Percent Possible (Observed) | R Merge I (Observed) | Mean I Over Sigma (Observed) | Redundancy | Number Unique Reflections (All) | |||||||||||
| 1 | 2.8 | 2.9 | 88.2 | 0.86 | 1.5 | 2.6 | |||||||||||||
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| t_other_torsion | 2.98 |
| t_omega_torsion | 2.33 |
| t_angle_deg | 1.05 |
| t_bond_d | 0.009 |
| t_dihedral_angle_d | |
| t_incorr_chiral_ct | |
| t_pseud_angle | |
| t_trig_c_planes | |
| t_gen_planes | |
| t_it | |
| Sample |
|---|
| Pseudomonas phage phi6 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 56448 |
| Reported Resolution (Å) | 9.1 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | Cross-correlation coefficient | ||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 QUANTUM (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 0.7 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI POLARA 300 |
| Minimum Defocus (nm) | |
| Maximum Defocus (nm) | |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | OTHER |
| Nominal Magnification | |
| Calibrated Magnification | 37037 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| IMAGE ACQUISITION | SerialEM | |
| CTF CORRECTION | CTFFIND | 3 |
| CTF CORRECTION | RELION | 1.4 |
| MODEL FITTING | UCSF Chimera | 1.12 |
| CLASSIFICATION | RELION | 1.4 |
| RECONSTRUCTION | RELION | 1.4 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 159492 | |||














