5ME0

Structure of the 30S Pre-Initiation Complex 1 (30S IC-1) Stalled by GE81112


ELECTRON MICROSCOPY
Sample
30S Pre-Initiation Complex Stalled by GE81112
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles23112
Reported Resolution (Å)13.5
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (4YBB, 3JCN, 3JCN, 1HR0, 2IFE, 1TIF)
Refinement Space
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsThe fitting of the model to the EM volume was performed through rigid body fitting. The head and the body of the 30S were treated as independent bodie ...The fitting of the model to the EM volume was performed through rigid body fitting. The head and the body of the 30S were treated as independent bodies. Due to the low resolution of the volume, the conformation of the linking bases was not minimized. In addition, some of the clashes of the model are produced by flexible loops or protein side chains that were not refined.
Data Acquisition
Detector TypeGATAN ULTRASCAN 4000 (4k x 4k)
Electron Dose (electrons/Å**2)17
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelJEOL 2200FSC
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder ModelGATAN LIQUID NITROGEN
Nominal Magnification50000
Calibrated Magnification74183
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION1.4
IMAGE ACQUISITIONDigitalMicrograph
CTF CORRECTIONCTFFIND4
MODEL FITTINGSitus
INITIAL EULER ASSIGNMENTRELION1.4
FINAL EULER ASSIGNMENTRELION1.4
CLASSIFICATIONRELION1.4
RECONSTRUCTIONRELION1.4
MODEL REFINEMENTCoot0.8.3
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION174142