Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
---|
1 | 3D HNCACB | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
2 | 3D HN(COCA)CB | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
3 | 3D HNCO | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
4 | 3D HN(CA)CO | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
5 | 3D HBHA(CO)NH | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
6 | 3D H(CCO)NH | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
7 | 3D 1H-15N NOESY | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
8 | 3D 1H-13C NOESY | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 99.96% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
10 | 3D HCCH-COSY | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 99.96% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
9 | 3D HCAN | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 99.96% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
11 | 3D HCA(CO)N | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 99.96% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
12 | 3D IPAP-HNCO(CA) | 300 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 90% H2O/10% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
13 | 3D IPAP-HNCO(CA) | 356 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 90% H2O/10% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
19 | 3D IPAP-HNCO | 300 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 90% H2O/10% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
18 | 3D IPAP-HNCO | 356 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 90% H2O/10% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
21 | 2D 1H-15N HSQC | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 95% H2O/5% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |
20 | 2D 1H-13C HSQC | 800 uM [U-99% 13C; U-99% 15N] KaiB mutant in foldswitched state | 99.96% D2O | 0.100 mM | 7 | 1 atm | 25 | Bruker AVANCE III 600 |