☰ Navigation Tabs
Structural basis for targeting and elongation arrest of Bacillus signal recognition particle
Sample BACILLUS SUBTILIS MIFM STALLED RIBOSOME IN COMPLEX WITH SIGNAL RECOGNITION PARTICLE (SRP)
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details VITRIFICATION 1 -- CRYOGEN- ETHANE, INSTRUMENT- FEI VITROBOT MARK IV,
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 75900 Reported Resolution (Å) 7 Resolution Method Other Details SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2843. (DEPOSITION ID: 12993). Refinement Type Symmetry Type POINT Point Symmetry C1
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol RIGID BODY FIT Refinement Target Overall B Value Fitting Procedure Details METHOD--RIGID BODY
Data Acquisition Detector Type TVIPS TEMCAM-F816 (8k x 8k) Electron Dose (electrons/Å**2) 20
Imaging Experiment 1 Date of Experiment 2013-12-10 Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 4000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version RECONSTRUCTION SPIDER
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details MICROGRAPH