Helical reconstruction of ACAP1(BAR-PH domain) decorated membrane tubules by cryo-electron microscopy
ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 4NSW | |
| Sample |
|---|
| BAR-PH DOMAIN OF ACAP1 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | HELICAL ARRAY |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | LIQUID ETHANE |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | 352 |
| Reported Resolution (Å) | 17 |
| Resolution Method | |
| Other Details | PARTICLES WERE CLASSIFIED BY THEIR DIAMETERS, THEN SHRUNK 4 TIMES TO PERFORM SINGLE PARTICLE RECONSTRUCTION USING IHRSR. SUBMISSION BASED ON EXPERIMEN ... |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (4NSW) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | Cross-correlation coefficient | ||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | METHOD--RIGID BODY FITTING AND MANUALLY DOCKING REFINEMENT PROTOCOL--X-RAY | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN ULTRASCAN 4000 (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 20 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2012-07-16 |
| Temperature (Kelvin) | 98 |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 2500 |
| Maximum Defocus (nm) | 3500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | 75000 |
| Calibrated Magnification | 125418 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details | GOOD MICROGRAPHS (VERIFIED BY HELICAL DIFFRACTION PATTERN) WERE SELECTED MANUALLY. THE ELECTRON DOSE IS 2000 ELECTRON PER NANOMETER SQUARE. |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| MODEL FITTING | UCSF Chimera | |
| RECONSTRUCTION | IHRSR | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| CTFFIND3 | ||||