4A8A

Asymmetric cryo-EM reconstruction of E. coli DegQ 12-mer in complex with lysozyme


ELECTRON MICROSCOPY
Sample
ESCHERICHIA COLI DEGQ GALLUS GALLUS LYSOZYME
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification DetailsVITRIFICATION 1 -- CRYOGEN- ETHANE, INSTRUMENT- MANUAL PLUNGER, METHOD- BLOT FOR 2 SECONDS BEFORE PLUNGING,
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles13432
Reported Resolution (Å)14.2
Resolution Method
Other DetailsSUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-1981. (DEPOSITION ID: 10364).
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (3STJ)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsMETHOD--RIGID BODY AND FLEXIBLE FITTING REFINEMENT PROTOCOL--X-RAY
Data Acquisition
Detector TypeKODAK SO-163 FILM
Electron Dose (electrons/Å**2)15
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)91
Microscope ModelFEI TECNAI F20
Minimum Defocus (nm)1000
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)-0.1
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification50000
Calibrated Magnification50000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging DetailsLOW DOSE MODE
EM Software
TaskSoftware PackageVersion
MODEL FITTINGFlex-EM
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONIMAGIC5
RECONSTRUCTIONSPIDER
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING