3J7E

Electron cryo-microscopy of human papillomavirus 16 and H16.V5 Fab fragments


ELECTRON MICROSCOPY
Sample
Mature HPV16 quasivirus capsid complexed with H16.V5 Fabs
Sample Components
Human papillomavirus 16
H16.V5 Fab
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentGATAN CRYOPLUNGE 3
Cryogen NameETHANE
Sample Vitrification DetailsBlot for 0.7 seconds before plunging into liquid ethane (GATAN CRYOPLUNGE 3).
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles2075
Reported Resolution (Å)13.6
Resolution MethodFSC 0.5 CUT-OFF
Other DetailsSemi-automatic particle selection was performed using e2boxer.py to obtain the particle coordinates, followed by particle boxing, linearization, norma ...Semi-automatic particle selection was performed using e2boxer.py to obtain the particle coordinates, followed by particle boxing, linearization, normalization, and apodization of the images using Robem. Defocus and astigmatism values to perform contrast transfer function (CTF) correction were assessed using Robem for the extracted particles. The icosahedrally averaged reconstructions were initiated using a random model generated with setup_rmc and reached 14 A resolution estimated at a Fourier Shell Correlation (FSC) of 0.5. For the last step of refinement, the final maps were CTF-corrected using a B factor of 200 A2. (Single particle--Applied symmetry: I)
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--flexible
Data Acquisition
Detector TypeGATAN ULTRASCAN 4000 (4k x 4k)
Electron Dose (electrons/Å**2)15
Imaging Experiment1
Date of Experiment2013-10-30
Temperature (Kelvin)95
Microscope ModelJEOL 2100
Minimum Defocus (nm)690
Maximum Defocus (nm)3990
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder ModelGATAN LIQUID NITROGEN
Nominal Magnification80000
Calibrated Magnification
SourceLAB6
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGSitus
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONAuto3DEM
RECONSTRUCTIONEMAN2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
Each particle