ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 4HNA | |
| Sample |
|---|
| Microtubule decorated with monomeric human kinesin (K349 construct) having an empty nucleotide pocket |
| Sample Components |
| Human monomeric kinesin-1A construct |
| Alpha-tubulin |
| Beta-tubulin |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | FILAMENT |
| Vitrification Instrument | HOMEMADE PLUNGER |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | No glow discharge was applied. After sample application to grid, liquid was mostly 'wicked' away by edgewise application of filter paper. Subsequentl ... |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | 120783 |
| Reported Resolution (Å) | 5 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | Initial alignment was done using customized SPIDER scripts. Reconstruction and subsequent refinement were done by FREALIGN. |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Axial Symmetry | C1 |
| Axial Rise | 8.78 |
| Angular Rotation | 25.77 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (4HNA, 4HNA, 4HNA) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | RMSD from the starting structure was monitored for convergence. | ||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | REFINEMENT PROTOCOL--flexible DETAILS--MDFF was performed using explicit solvation. Side chains were excluded from the MDFF target potential. Followi ... | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 15 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2013-04-15 |
| Temperature (Kelvin) | |
| Microscope Model | FEI TECNAI F30 |
| Minimum Defocus (nm) | 1000 |
| Maximum Defocus (nm) | 2500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | GATAN LIQUID NITROGEN |
| Nominal Magnification | 130000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details | 8K x 8K super-resolution mode was used. 10 frames total were collected. |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| MODEL FITTING | MDFF | |
| RECONSTRUCTION | FREALIGN | |
| RECONSTRUCTION | SPIDER | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| done within FREALIGN | ||||