☰ Navigation Tabs
Remodeling of actin filaments by ADF cofilin proteins
Sample actin decorated with cofilin
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK I Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles Reported Resolution (Å) 9 Resolution Method FSC Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 27.6 Angular Rotation 162.1
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type KODAK SO-163 FILM Electron Dose (electrons/Å**2)
Imaging Experiment 1 Date of Experiment 2010-01-01 Temperature (Kelvin) Microscope Model FEI TECNAI F20 Minimum Defocus (nm) 1100 Maximum Defocus (nm) 5300 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2 Imaging Mode BRIGHT FIELD Specimen Holder Model GATAN LIQUID NITROGEN Nominal Magnification 50000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version RECONSTRUCTION IHRSR RECONSTRUCTION SPIDER
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details each EM