SOLUTION SCATTERING
| Solution Scattering Data Acquistion | 1 |
|---|---|
| Scattering Type | x-ray |
| Radiation/Neutron Source | ESRF GRENOBLE |
| Synchrotron | Y |
| Beamline Type | IDO2 |
| Detector Type | FRELON CCD CAMERA |
| Detector Manufacturer Details | |
| Temperature (K) | 293 |
| pH | 7.4 |
| Numer of Time Frames Used | 10 |
| Protein Concentration Range (mg/mL) | 0.40 |
| Sample Buffer | 250 MM NACL 2.7 MM KCL 8.1 MM NAH2PO4 1.5 MM KH2PO4 |
| Data Reduction Software | MULTICCD |
| Guiner Mean Radius Of Gyration (nm) | 9.22 |
| Sigma Mean Radius Of Gyration | 0.56 |
| R(XS-1) Mean Cross Sectional Radii (nm) | 2.31 |
| R(XS-1) Sigma Mean Cross Sectional Radii | 0.09 |
| R(XS-2) Mean Cross Sectional Radii (nm) | 1.52 |
| R(XS-2) Sigma Mean Cross Sectional Radii | 0.09 |
| P(R) Protein Length (nm) | 1 |
| Solution Scattering Data Analysis and Model Fitting | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Method | Software | Software Authors | Starting Model | Conformers, Number Calculated | Conformers, Number Submitted | Conformers, Selection Criteria | Best Representative Conformer | Other Details | |||||||||||
| INSIGHT II, SCTPL7, GNOM | 5000 | 8 | STRUCTURES WITH THE LOWEST GOODNESS-OF-FIT R-FACTOR AFTER FILTERING ON RG AND RXS-1 | 1 | |||||||||||||||
Diffraction
| Radiation Source | |||||
|---|---|---|---|---|---|
| ID # | Source | Type | Wavelength List | Synchrotron Site | Beamline |
| 1 | SYNCHROTRON | ESRF BEAMLINE ID2 | 1.0 | ESRF | ID2 |