Skip to main content

 34ZG | pdb_000034zg

Cryo-EM structure of a near-planar 13-mer ring formed by recombinant human parainfluenza virus type 2 nucleoprotein


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelOther 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d10.304
f_angle_d0.394
f_chiral_restr0.037
f_plane_restr0.004
f_bond_d0.002
Sample
Recombinant HPIV2 nucleoprotein 13-mer ring
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsGlow-discharge details: 45 s; glow-discharge pressure:38 Pa; glow-discharge details: PELCO easiGlow, 12 mA. Blot force 1; wait time 10 s; blot time 6 ...Glow-discharge details: 45 s; glow-discharge pressure:38 Pa; glow-discharge details: PELCO easiGlow, 12 mA. Blot force 1; wait time 10 s; blot time 6 s.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles430693
Reported Resolution (Å)2.91
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsFinal C13 non-uniform refinement in cryoSPARC v4.6.2 used 430,693 particles from the selected ring-like ab initio class. The reconstruction reached th ...Final C13 non-uniform refinement in cryoSPARC v4.6.2 used 430,693 particles from the selected ring-like ab initio class. The reconstruction reached the highest sampled spatial-frequency shell and was reported by cryoSPARC at a nominal, sampling-limited resolution of 2.91 A using the corrected masked gold-standard FSC criterion (0.143); the corrected masked GS-FSC remained above 0.143 at this boundary. The unmasked half-map FSC crossed 0.143 at 3.17 A. Independent half maps generated during C13 non-uniform refinement were used for gold-standard FSC calculation. The nominal 2.91 A C13 reconstruction was used for atomic model building and refinement.
Refinement Type
Symmetry TypePOINT
Point SymmetryC13
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetMap-model agreement and stereochemical geometry
Overall B Value
Fitting Procedure
DetailsInitial rigid-body placement was performed in UCSF ChimeraX using Fit in Map, followed by iterative real-space refinement in PHENIX and local flexible ...Initial rigid-body placement was performed in UCSF ChimeraX using Fit in Map, followed by iterative real-space refinement in PHENIX and local flexible fitting/correction in ISOLDE. Final PHENIX real-space refinement used global coordinate minimization, individual isotropic ADP refinement, NCS constraints, and secondary-structure restraints.
Data Acquisition
Detector TypeTFS FALCON 4i (4k x 4k)
Electron Dose (electrons/Å**2)47.4
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)3300
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification96000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.6.2
PARTICLE SELECTIONTopaz0.2.5a
IMAGE ACQUISITIONEPU3.8
CTF CORRECTIONcryoSPARC4.6.2
MODEL FITTINGUCSF ChimeraX1.11.1 (2026-01-23)
MODEL FITTINGISOLDE
INITIAL EULER ASSIGNMENTcryoSPARC4.6.2
FINAL EULER ASSIGNMENTcryoSPARC4.6.2
CLASSIFICATIONcryoSPARC4.6.2
RECONSTRUCTIONcryoSPARC4.6.2
MODEL REFINEMENTPHENIX1.21.2_5419
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONcryoSPARC, version 4.6.2 Patch CTF estimation; CTF parameters incorporated during reconstruction/refinement.862484Topaz-assisted particle picking and iterative 2D classification, followed by template picking and further 2D classification.