SOLUTION NMR
| NMR Experiment | ||||||||
|---|---|---|---|---|---|---|---|---|
| Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
| 1 | NOESY | 75 mM NaPi 50 mM NaCl | 7.25 | AMBIENT | 303 | |||
| 2 | 3D_13C-separated_NOESY | 75 mM NaPi 50 mM NaCl | 7.25 | AMBIENT | 303 | |||
| 3 | 3D_15N-separated_NOESY | 75 mM NaPi 50 mM NaCl | 7.25 | AMBIENT | 303 | |||
| NMR Spectrometer Information | |||
|---|---|---|---|
| Spectrometer | Manufacturer | Model | Field Strength |
| 1 | Bruker | AVANCE | 600 |
| 2 | Varian | INOVA | 800 |
| NMR Refinement | ||
|---|---|---|
| Method | Details | Software |
| RG refinement | CYANA | |
| NMR Ensemble Information | |
|---|---|
| Conformer Selection Criteria | energy minimized average structure |
| Conformers Calculated Total Number | 1 |
| Conformers Submitted Total Number | 1 |
| Representative Model | 1 (minimized average structure) |
| Additional NMR Experimental Information | |
|---|---|
| Details | RG based on SANS experiment |
| Computation: NMR Software | ||||
|---|---|---|---|---|
| # | Classification | Version | Software Name | Author |
| 1 | structure solution | CYANA | 2.1.4 | P.GUNTERT ET AL. |
| 2 | refinement | X-PLOR | 3 | |