2GUT

Solution structure of the trans-activation domain of the human co-activator ARC105


SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
1HNCA1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
2HNCOCA1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
3HNCACB1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
4HNCOCACB1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
5HNCO1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
6HNCACO1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
7HN(COCA)NH1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
8N15noesy1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
9tocsy1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
10CCONH1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
11HCCONH1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
12aliphatic1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
13aromatic-C13noesy1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
14HCCHTOCSY1mM arc105 U-15N, 13C, 30mM NaCl, 10mM phosphate buffer, 90% H2O, 10% D2O90% H2O/10% D2O30 mM NaCl6.8ambient298
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE750
2VarianINOVA600
3BrukerAVANCE500
NMR Refinement
MethodDetailsSoftware
simulated annealing using CYANAPROSA
NMR Ensemble Information
Conformer Selection Criterialowest NOE target function with no NOE violations > 0.5 A, and angular violations > 5 deg
Conformers Calculated Total Number20
Conformers Submitted Total Number15
Representative Model1 (lowest energy)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1processingPROSA3.7GUNTERT
2data analysisCARA1.5KELLER
3structure solutionCYANA2.1GUNTERT
4refinementCYANA2.1GUNTERT