SOLUTION NMR
| NMR Experiment | ||||||||
|---|---|---|---|---|---|---|---|---|
| Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
| 1 | 3D_15N-separated_NOESY | Uniform (random) labeling with 15N | 90% H2O/10% D2O | 150 mM NaCl | 7.4 | ambient | 298 | |
| 2 | 3D_13C-separated_NOESY | Uniform (random) labeling with 15N, 13C | 90% H2O/10% D2O | 150 mM NaCl | 7.4 | ambient | 298 | |
| NMR Spectrometer Information | |||
|---|---|---|---|
| Spectrometer | Manufacturer | Model | Field Strength |
| 1 | Bruker | DRX | 600 |
| 2 | Bruker | AVANCE | 600 |
| NMR Refinement | ||
|---|---|---|
| Method | Details | Software |
| Simulated Annealing with XPLOR NHI followed by water refinement | XwinNMR | |
| NMR Ensemble Information | |
|---|---|
| Conformer Selection Criteria | closest to average after water refinement |
| Conformers Calculated Total Number | 200 |
| Conformers Submitted Total Number | 20 |
| Computation: NMR Software | ||||
|---|---|---|---|---|
| # | Classification | Version | Software Name | Author |
| 1 | collection | XwinNMR | Bruker, Rheinstetten | |
| 2 | processing | XwinNMR | Bruker, Rheinstetten | |
| 3 | processing | Azara | Wayne Boucher | |
| 4 | data analysis | ANSIG | 3.3 | Per Kraulis |
| 5 | structure solution | X-PLOR | Brunger | |
| 6 | refinement | X-PLOR | Brunger | |