☰ Navigation Tabs
Cannabinoid Receptor 1-Gi Complex
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 6.326 f_angle_d 0.538 f_chiral_restr 0.041 f_plane_restr 0.004 f_bond_d 0.003
Sample Cannabinoid receptor 1
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 231363 Reported Resolution (Å) 2.42 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON IV (4k x 4k) Electron Dose (electrons/Å**2) 52
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 700 Maximum Defocus (nm) 1500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 4.00 MODEL REFINEMENT PHENIX 1.19.2_4158 RECONSTRUCTION RELION 4.00
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION