Cryo-em structure of human coxsackievirus A21 complexed with five domain icam-1kilifi
ELECTRON MICROSCOPY
| Sample |
|---|
| COXSACKIEVIRUS A21/ICAM- 1KILIFI COMPLEX |
| Sample Components |
| HUMAN COXSACKIEVIRUS A21 VP1 1073-1286 |
| human coxsackievirus A21 VP2 2010-2272 |
| human coxsackievirus A21 VP3 3043-3234 |
| human coxsackievirus A21 VP1 1287-1298 |
| human coxsackievirus A21 VP3 3035-3239 |
| ICAM-1KILIFI |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | REICHERT-JUNG PLUNGER |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | PLUNGED INTO ETHANE AT LIQUID NITROGEN TEMPERATURE |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 4704 |
| Reported Resolution (Å) | 8 |
| Resolution Method | |
| Other Details | A B-FACTOR OF 589.46 WAS SET FOR ALL THE ATOMS BASED ON THE EQUATION OF -4*LN(0.1*RESOLUTION2) TO MIMIC A 8 ANGSTROM RESOLUTION CRYOEM STRUCTURE. OCCU ... |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | I |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (1IAM, 1Z7S) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | BEST SUMF VALUE FIT USING THE PROGRAM EMFIT | ||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | REFINEMENT PROTOCOL--RIGID BODY | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | KODAK SO-163 FILM | ||||||||
| Electron Dose (electrons/Å**2) | 26 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2001-03-15 |
| Temperature (Kelvin) | 100 |
| Microscope Model | FEI/PHILIPS CM300FEG/T |
| Minimum Defocus (nm) | 700 |
| Maximum Defocus (nm) | 3000 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | 45000 |
| Calibrated Magnification | 47000 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details | SAMPLES WERE MAINTAINED AT LIQUID NITROGEN TEMPERATURES IN THE ELECTRON MICROSCOPE. |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| MODEL FITTING | EMfit | |
| RECONSTRUCTION | EM3DR | |
| RECONSTRUCTION | PFT | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| REVERSED CTF WITH WEINER FACTOR FOR EACH PARTICLE | ||||