7TY6

Cryo-EM structure of human Anion Exchanger 1 bound to 4,4'-Diisothiocyanatodihydrostilbene-2,2'-Disulfonic Acid (H2DIDS)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg30.234
r_dihedral_angle_3_deg13.957
r_lrange_it11.821
r_lrange_other11.821
r_dihedral_angle_4_deg11.769
r_scangle_it7.692
r_scangle_other7.691
r_mcangle_it7.034
r_mcangle_other7.033
r_dihedral_angle_1_deg5.023
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg30.234
r_dihedral_angle_3_deg13.957
r_lrange_it11.821
r_lrange_other11.821
r_dihedral_angle_4_deg11.769
r_scangle_it7.692
r_scangle_other7.691
r_mcangle_it7.034
r_mcangle_other7.033
r_dihedral_angle_1_deg5.023
r_scbond_it4.689
r_scbond_other4.689
r_mcbond_it4.324
r_mcbond_other4.324
r_angle_other_deg2.291
r_angle_refined_deg1.282
r_symmetry_nbd_other0.188
r_nbtor_refined0.156
r_nbd_refined0.155
r_xyhbond_nbd_refined0.113
r_symmetry_xyhbond_nbd_other0.093
r_symmetry_nbtor_other0.069
r_chiral_restr0.052
r_bond_other_d0.032
r_gen_planes_other0.013
r_gen_planes_refined0.01
r_bond_refined_d0.003
Sample
Dimeric anion exchanger 1 (SLC4A1)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification DetailsBlot force 3 for 3-5 seconds was used and subsequent grids were screened for ice thickness prior to data collection
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles267008
Reported Resolution (Å)2.98
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (4YZF)
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)51.85
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification64000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
IMAGE ACQUISITIONLeginon
CTF CORRECTIONcryoSPARC
MODEL FITTINGUCSF ChimeraX
INITIAL EULER ASSIGNMENTcryoSPARC
FINAL EULER ASSIGNMENTcryoSPARC
CLASSIFICATIONcryoSPARC
RECONSTRUCTIONcryoSPARC
MODEL REFINEMENTREFMACservalcat
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION2460255