7T54

Cryo-EM structure of ATP-bound PCAT1 in the outward-facing conformation


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.434
f_angle_d0.54
f_chiral_restr0.04
f_plane_restr0.003
f_bond_d0.002
Sample
PCAT1 homodimer
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles98523
Reported Resolution (Å)4.5
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (4RY2)
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value80
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)1.5
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3
CTF CORRECTIONCTFFIND4.0
MODEL FITTINGREFMACCCP4 version 7.0
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTcryoSPARC2
CLASSIFICATIONRELION3.0
RECONSTRUCTIONcryoSPARC2
MODEL REFINEMENTCoot0.8.9.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY1500000