7SIN

Structure of negative allosteric modulator-bound inactive human calcium-sensing receptor


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d16.19
f_angle_d0.515
f_chiral_restr0.041
f_plane_restr0.004
f_bond_d0.002
Sample
Homodimer human calcium sensing receptor
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot for 6 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles161574
Reported Resolution (Å)5.9
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsLocal ECD 4.0A Local TM 4.2A
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1 (5K5S, 5K5S)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)58.63
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsPreliminary grid screening was performed manually.
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC2.16
IMAGE ACQUISITIONLeginon
CTF CORRECTIONcryoSPARC2.16
MODEL FITTINGCoot0.9.1
MODEL REFINEMENTPHENIX1.14
INITIAL EULER ASSIGNMENTcryoSPARC2.16
FINAL EULER ASSIGNMENTcryoSPARC3.0
RECONSTRUCTIONcryoSPARC3.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1241782