7R8E

The structure of human ABCG1 E242Q complexed with ATP


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg28.122
r_dihedral_angle_3_deg16.506
r_dihedral_angle_4_deg16.265
r_dihedral_angle_1_deg6.892
r_long_range_B_refined4.627
r_long_range_B_other4.627
r_mcangle_it1.726
r_mcangle_other1.725
r_angle_refined_deg1.404
r_scangle_other1.242
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg28.122
r_dihedral_angle_3_deg16.506
r_dihedral_angle_4_deg16.265
r_dihedral_angle_1_deg6.892
r_long_range_B_refined4.627
r_long_range_B_other4.627
r_mcangle_it1.726
r_mcangle_other1.725
r_angle_refined_deg1.404
r_scangle_other1.242
r_angle_other_deg1.127
r_mcbond_it0.955
r_mcbond_other0.955
r_scbond_it0.67
r_scbond_other0.67
r_chiral_restr0.065
r_gen_planes_refined0.004
r_bond_refined_d0.003
r_bond_other_d0.002
r_gen_planes_other0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
ABCG1 transporter with cholesterol and ATP bound
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles72323
Reported Resolution (Å)3.7
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)60
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1443662