7Q8B

Leishmania major actin filament in ADP-Pi state


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d8.832
f_angle_d0.4962
f_chiral_restr0.0458
f_plane_restr0.0035
f_bond_d0.0028
Sample
Polymerized actin
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles89543
Reported Resolution (Å)3.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise27.77
Angular Rotation-166.61
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)45
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGUCSF Chimera1.14
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
CLASSIFICATIONRELION3.1
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTPHENIX1.19.2-4158-000
MODEL REFINEMENTISOLDE1.1.1
MODEL REFINEMENTUCSF ChimeraX1.1.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION