7NYC

cryoEM structure of 3C9-sMAC


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_mcbond_it87.158
r_dihedral_angle_2_deg32.648
r_dihedral_angle_4_deg17.985
r_dihedral_angle_3_deg12.117
r_dihedral_angle_1_deg10.337
r_angle_refined_deg2.096
r_chiral_restr0.133
r_gen_planes_refined0.017
r_bond_refined_d0.013
r_bond_other_d
RMS Deviations
KeyRefinement Restraint Deviation
r_mcbond_it87.158
r_dihedral_angle_2_deg32.648
r_dihedral_angle_4_deg17.985
r_dihedral_angle_3_deg12.117
r_dihedral_angle_1_deg10.337
r_angle_refined_deg2.096
r_chiral_restr0.133
r_gen_planes_refined0.017
r_bond_refined_d0.013
r_bond_other_d
r_angle_other_deg
r_gen_planes_other
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_mcbond_other
r_mcangle_it
r_mcangle_other
r_scbond_it
r_scbond_other
r_scangle_it
r_scangle_other
r_long_range_B_refined
r_long_range_B_other
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
3C9-sMAC
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles85151
Reported Resolution (Å)3.54
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (6H03, 6H04, 4A5W, 2WCY, 6CXO)
Refinement Space
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)40
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcrYOLO
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4-1
MODEL FITTINGUCSF ChimeraX
MODEL FITTINGCoot9.1
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTISOLDE
MODEL REFINEMENTCoot9.1
MODEL REFINEMENTREFMAC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION