6WCB

Human open state TMEM175 in CsCl


ELECTRON MICROSCOPY
Sample
Human open state TMEM175 in CsCl
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsBlot for 4 seconds prior to plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles94653
Reported Resolution (Å)3.17
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement TargetFSC
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)61
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND4.1.10
MODEL FITTINGPHENIXdev-3751
MODEL REFINEMENTPHENIXdev-3751
INITIAL EULER ASSIGNMENTcryoSPARC2.12
FINAL EULER ASSIGNMENTcryoSPARC2.12
CLASSIFICATIONcryoSPARC2.12
RECONSTRUCTIONcryoSPARC2.12
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION4275219