6VWS

Hexamer of Helical HIV capsid by RASTR method


ELECTRON MICROSCOPY
Sample
Hexamer of helical HIV capsid protein
Specimen Preparation
Sample Aggregation StateHELICAL ARRAY
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles245050
Reported Resolution (Å)6.08
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsA non-helical approach (RASTR) to calculate a volume from the same subset of data used for helical analysis. The position and rotation to the center o ...A non-helical approach (RASTR) to calculate a volume from the same subset of data used for helical analysis. The position and rotation to the center of a single hexamer in the final helical volume was determined and used along the final refined helical rise and twist to extract a total of 245050 unique particles from which surrounding tube density was subtracted by reprojection using Relion. The resulting stack of 245050 particles, each extracted into a 192 multiple 192 pixel box centered around the chosen asymmetric unit for each subtracted volume, was imported into Cryosparc. 2D clustering and ab-initio heterogeneous reconstruction with 4 volumes were then used to select a subset of 96392 particle images. These images, along with the cleanest reference from ab-initio volume determination were then used to obtain a volume through 3D Refinement.
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise7.61
Angular Rotation150.32
Map-Model Fitting and Refinement
Id1 (6VKV)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value204.64
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)47.36
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)1200
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification28000
Calibrated Magnification28000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0.4
IMAGE ACQUISITIONLeginon
CTF CORRECTIONCTFFIND4.0
MODEL FITTINGUCSF Chimera
INITIAL EULER ASSIGNMENTRELION3.0.4
FINAL EULER ASSIGNMENTRELION3.0.4
CLASSIFICATIONcryoSPARC2.0
RECONSTRUCTIONcryoSPARC2.0
MODEL REFINEMENTPHENIX3758
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE146291A total of 208,225helical segments were extracted from manually selected, well-ordered helical tubes using Relion